International Journal of Physical Sciences
Subscribe to IJPS
Full Name*
Email Address*

Article Number - 060876B63495


Vol.12(5), pp. 52-59 , March 2017
DOI: 10.5897/IJPS2016.4592
ISSN: 1992-1950



Full Length Research Paper

Pressure and temperature effects on corona onset voltage in electrostatic precipitators



Fadhil Khaddam Fuliful
  • Fadhil Khaddam Fuliful
  • Physics Department, College of Science, Karbala University, Karbala, Iraq.
  • Google Scholar







 Received: 16 December 2016  Accepted: 08 March 2017  Published: 16 March 2017

Copyright © 2017 Author(s) retain the copyright of this article.
This article is published under the terms of the Creative Commons Attribution License 4.0


Corona onset voltage is one of the most important factors that determine the charging toxic particle in an industrial application. Electrostatic precipitators (ESP) remove the suspended particle with a gas inlet. This paper developed Peek's formula to estimate the maximum electric field near the discharge wire in corona discharge models, the values of maximum electric field and corona onset voltage near the discharge wires have been calculated for different values of pressure and temperature for confined gas in a region between the electrodes in ESP. The model uses finite difference method (FDM) to solve governing equations (Poisson’s and current continuity equations) simultaneously. Computer simulation method uses FORTRAN program to estimate potential distribution and maximum electric field intensity. The calculated corona onset voltage values are compared with the calculated values of different models. 

 

Key words: Corona onset voltage, corona discharge, electric field distribution, electrostatic precipitators.

EL-Bahy MM, Abouelsaad M, Abdel-Gawad N, Badawi M (2007). Onset voltage of negative corona on stranded conductors. J. Phys. D: Appl. Phys. 40:1-8.
 
Eroncel C, Ilhan S, Ozdemir A, Kaypmaz A (2010). Corona Onset Voltage and Corona Power Losses in an Indoor Corona Cage, Proceedings of the 14th International Middle East Power Systems Conference (MEPCON'10), Cairo University, Egypt, December 19-21, 2010, Paper ID 286.
 
Goldman M, Sigmond RS, Nicole R (1982). Corona and Insulation. IEEE Trans. Electr. Insul. EI-17(2).
Crossref
 
James HT, Phil AL, Toshiaki Y, David WC (1995). Electrostatic Precipitators, Research Triangle Institute 1995.
 
Kalenderli Ö, Önal E, Altay Ö (2001). Computing the Corona Onset and the Utilization Factor of Rod-Plane Electrode by Using Charge Simulation Method. Electrical Insulation Conference and Electrical Coil &Winding Conference, October 2001. Manufacturing.
Crossref
 
Konstantios NK, Antonios XM, Emmanouil DF (2013).Finite element analysis method for detection of the corona discharge inception voltage in a wire-cylinder arrangement. Recent Advances in Finite Differences and Applied & Computational Mathematics, Mathematics and Computers in Science and Engineering Series, 12:188-193.
 
Kuffel E, Zaengl WS, Kuffel J (2000). High Voltage Engineering Fundamentals. Second Edition, 2000.
 
Nicolae PG, Vaida V, Iagar A, Dinis CM (2008). Improvement of Technological and Electric Performances for Plate Type Electrostatic Precipitators with Three Sections. Wseas Trans. Power Syst. 3(8).
 
Olsen RG, Phillips DB, Pedrow PD (1997). Extrapolation of a corona Streamer 1Onset criterion to general convex conductor surface" 10th International on High Voltage Engineering, August 1997.
 
Qiu Y (1986). Simple Expression of Field Non uniformity Factor for Hemispheric ally Capped Rod-Plane Gaps. IEEE Trans. Electr. Insul. EI-21(4).
Crossref
 
Souza AL, Lopes IJS (2008). Corona Onset Models: A Computational and Experimental Evaluation. In Electrical Insulation and Dielectric Phenomena, 2008. CEIDP 2008. Annual Report Conference on (pp. 698-701).
Crossref
 
Van Thanh D, Bui TX, Tran TT, Phan CD, Terebessy HT (2016c). Corona Based Air-Flow Using Parallel Discharge Electrodes. Exp. Therm. Fluid Sci. 79:52-56.
Crossref
 
Van Thanh D, Thien XD, Tibor T, Tung TB (2016b). Bipolar corona discharge based air flow generation with low net charge. Sens. Actuators A. 244:146–155.
Crossref
 
Van Thanh D, Tung TB, Thien XD, Tibor T (2016a). Pressure sensor based on bipolar discharge corona configuration. Sens. Actuators A 237:81-90.
Crossref
 
Zangeneh A, Gholami A (2005). A New Method for Calculation of Corona Inception Voltage in Stranded Conductors of Overhead Transmission Lines, 20th International Power System Conference, 2005.
 
Ziedan H, Sayed A, Mizuno A, Ahmed A (2010). Onset Voltage of Corona Discharge in Wire-Duct Electrostatic Precipitators. Int. J. Plasma Environ. Sci. Technol. 4(1).

 


APA Fuliful, F. K. (2017). Pressure and temperature effects on corona onset voltage in electrostatic precipitators. International Journal of Physical Sciences, 12(5), 52-59.
Chicago Fadhil Khaddam Fuliful. "Pressure and temperature effects on corona onset voltage in electrostatic precipitators." International Journal of Physical Sciences 12, no. 5 (2017): 52-59.
MLA Fadhil Khaddam Fuliful. "Pressure and temperature effects on corona onset voltage in electrostatic precipitators." International Journal of Physical Sciences 12.5 (2017): 52-59.
   
DOI 10.5897/IJPS2016.4592
URL http://academicjournals.org/journal/IJPS/article-abstract/060876B63495