Full Length Research Paper

Physicochemical and microbiological evaluation of water from western part of the Rio Grande does Norte, Brazil

Manoel Marcelino da Silva
  • Manoel Marcelino da Silva
  • Departamento de Biociências – DBIO, UFERSA - Universidade Federal Rural Do Semi-Árido, Brazil.
  • Google Scholar
Francisco Marlon Carneiro Feijó
  • Francisco Marlon Carneiro Feijó
  • Departamento de Biociências – DBIO, UFERSA - Universidade Federal Rural Do Semi-Árido, Brazil.
  • Google Scholar
Nilza Dutra Alves
  • Nilza Dutra Alves
  • Departamento de Biociências – DBIO, UFERSA - Universidade Federal Rural Do Semi-Árido, Brazil.
  • Google Scholar
Gardênia Silvana de Oliveira Rodrigues
  • Gardênia Silvana de Oliveira Rodrigues
  • Departamento de Biociências – DBIO, UFERSA - Universidade Federal Rural Do Semi-Árido, Brazil.
  • Google Scholar
Caio Sergio Santos
  • Caio Sergio Santos
  • Departamento de Biociências – DBIO, UFERSA - Universidade Federal Rural Do Semi-Árido, Brazil.
  • Google Scholar
Fernando da Costa Fernandes
  • Fernando da Costa Fernandes
  • Departamento de Biociências – DBIO, UFERSA - Universidade Federal Rural Do Semi-Árido, Brazil.
  • Google Scholar


  •  Received: 30 January 2019
  •  Accepted: 06 March 2020
  •  Published: 30 April 2020

 ABSTRACT

The water quality evaluation with reference to parameters of drinkability is made through a series of analyses, which are physicochemical or microbiological. This study aims to evaluate the physicochemical and microbiological parameters of drinking water distribution network in the western part of the Rio Grande do Norte, Brazil. Water samples were collected in several neighborhoods, and divided into 5 zones. In each of those five points two samples were collected: Water receiver of water distribution network and household water collector. In relation to the physical parameters, color and turbidity recorded higher results in the collectors of homes, and identified the lack of maintenance. For the studied microbial tests, the presence of coliform group bacteria was verified, being the major contamination in the receivers. This was justified by the lack of maintenance and prohibition of sealing of these collectors, allowing the access of rodents, insects and other carriers of microorganisms.  Therefore, the water consumed at the collection points in the western zone of the RN / Brazil presents adequate physicochemical and microbiological indices in disagreement with the legislation that regulates water portability.
 
Key words: Water quality, coliforms, microorganisms, portability, water supply.
 


 INTRODUCTION

Water quality of public supplies, through chemical, physical and microbiological parameters, is an issue monitored by the government through regulatory agencies or consumers (Al-Mudhaf et al., 2009). There are so many reasons for that quality being compromised, such as some chemicals substances persistently remain stable to the conventional water treatment processes or simply by their cumulative effect (Inyang and Dickenson, 2015).
 
The composition  of  some  chemical products  used  in the water treatment or its components which are naturally present in the water and their potential adverse health effects associated with long-term ingestion have been studied by Choi et al. (2013); this drives to the importance of policies that regulate issues surrounding water portability parameters for human consumption.
 
Ordinance N° 2914 of 12 December 2011 of the Ministry of Health (Brazil, 2011) currently holds in Brazil and provides procedures for controlling and monitoring water quality for  human  consumption  and  its  portability
 
standards. This legislation rules establish actions of supplier agencies involved in the water treatment processes and control to provide potable water to the population respecting the proper hygienic and sanitary quality standards, through physical, chemical and microbiological indicators (Morais et al., 2016).
 
In the assessment of water quality, a set of parameters must be considered as well as their maximum permissible values (MPV) in accordance with Brazilian legislation (Silva et al., 2014). Among these parameters, the physicochemical has fundamental importance because these characteristics can influence the water taste, color and odor, and produce harmful physiological effects (Blank and Vieira, 2014). According to the studies that portray the water quality for human consumption, the main physical and chemical parameters evaluated are pH, hardness, chloride, nitrate, alkalinity, color and turbidity, with standards established by Ordinance 2.914 / 2011 (Sousa et al., 2016; Lima et al., 2016; Fernandes and Scalize, 2015).
 
Beyond the physicochemical parameters, potable water must be free of pathogenic microorganisms and indicator bacteria which determine contamination, highlighting the coliforms group, total coliforms (TC), thermotolerant coliforms (TTC) and Escherichia coli (Fatemeh et al., 2014). These bacteria may be responsible mainly for gastroenteritis which remains a huge concern for public health in developing countries and regions with small financial resources and poor hygiene conditions (Cabral, 2010).
 
According to Tong et al. (2016), about 88% of gastroenteritis cases in the world are attributed to contaminated water containing these bacteria, which are common in cases of inadequate sanitation or insufficient hygiene. Thus, it is important to develop research into the environmental monitoring and diagnosis, in order to strengthen the scientific basis in the area, thereby allowing the adoption of control measures and management of pollution sources (Oliveira et al., 2009).
 
Therefore, there is a need for verification on the quality of potable water delivered by the supplier agency to customers of the west RN/Brazil under the following optics: (A) water receiver of water distribution network in the households and (B) household water collector.


 MATERIALS AND METHODS

Samples and location of sampling
 
Water samples were collected in several neighborhoods near the municipality of Mossoró / RN, divided into 5 zones (North, South, East, West and Central). In each of those five points were collected two samples – (A) water receiver of water distribution network and (B) household water collector. Samples were collected following the sample storage guidance and preservation, considering the parameter to be analyzed according to Funasa (2006). Ten samples were collected in each recipient at 15 day intervals, in the months of July to November 2016, totaling 100 samples.
 
Analyses
 
Samples were subjected to analysis according to the Standard Methods for the Examination of Water and Wastewater (Eaton et al., 2012). They were processed at the Veterinary Microbiology Laboratory and at Petroleum Engineering Laboratory; both belong to the Federal Rural University of the Semiarid. The following analyses were carried out:
 
pH
 
Using the potentiometer, the electrometric pH measurement principle is the determination of the ionic activity of hydrogen using the standard hydrogen electrode, which consists of a platinum rod on which the hydrogen gas flows at a pressure of 101 kPa.
 
Hardness
 
This is done through the titration process by complexation, using a standard solution of EDTA (ethylenediaminetetraacetic acid).
 
Nitrate
 
This is done by the use of phenol disulfonic acid method, with spectrophotometer reading.
 
Chlorides
 
This was done with titration with Silver Nitrate, where the standard solution of silver nitrate was placed in a 50 mL burette and the titration was carried out until the colour changed from white to red. This procedure was repeated twice and compared with the with test (distilled water).
 
Alkalinity
 
Using titration with sulfuric acid, which is determined by potentiometry is done by titration with standard solution of H2SO4;
 
Colour
 
The colour determination is made by visually comparing the sample with a coloured glass disk, suitably calibrated with standard solutions of different concentrations of (K2PtCl6).
 
Turbidity
 
This is determined by the nephelometric method, using a Turbidímetro.
 
Microorganisms (total coliforms, thermotolerant coliforms and Escherichia coli): the most probable number (MPN) technique also known as multi-tube method was used. 25 mL of sample was prepared aseptically and three successive dilutions (10¹, 10² and 10³) were prepared and for each dilution three tubes containing 10 mL of Sodium Lauryl Sulfate Broth (LST) were used with inverted Durhan tubes, which were subsequently incubated at 35 to 37°C for 24 h. The positivity of the test was observed by the production of gas inside the tubes of Durhan.
 
Statistics
 
The     data    on     physicochemical    analyses    were    performed  using two tests for statistical treatment. The Kruskal-Wallis test was used to compare the parameters for the Zones (North, South, East, West and Central). In the samples collected on point A and B, were used the Wilcoxon test – Paired; the hypotheses are tested about equality of means or medians of dependent populations with unknown distributions (Spiegel et al., 2013). The Action Stat v.3.0 software developed by ESTATCAMP was used for the analysis.
 
In statistical microbiological analyses, data were tabulated in Microsoft Excel 2016 spreadsheet application. Logarithmic transformation was used (LOG) and comparing means was proceeded using the Tukey test, with the level of 5% probability. The software used in the analysis was the SAS (Cody and Smith, 2004).

 


 RESULTS AND DISCUSSION

The averages of results referring to  the  chemical parameters pH, hardness, chlorides, nitrates and alkalinity to the North, South, East, West and Central zones are described in Table 1. The averages of the two samples through the test Kruskal Wallis are described in the column identified by the letter X, which tests the statistical difference between the zones. The p-value represents the Wilcoxon test that describes the significance between A and B.
 
In the Western region, lowest values for pH in both Samples A and in B in the studied households were observed. This may be associated with the nature of the mineral soil, that can be acidic naturally s by a deficiency in the origin soil basis or by processes of soil forming that leads to a removal of basic elements such as K, Ca, Mg and Na. This result differs statistically from  the  other zones  (p > = 0.05);   however    is found to the extent required by law. There was no significant difference statistically in the pH measured between samples A and B (p = 0.758).
 
The default for pH tells that the pipes probably have no corrosion or fouling,  suggesting that water  used to supply at low pH values less than 4 may contribute to corrosiveness and values greater than 7 increase the possibility of fouling, highlighting the need for control (Sousa et al., 2016).
 
Hardness recorded in the water samples was between 29.3 and 218.8 mg/L, respectively on the East and West zones. These data are probably due to variation in the multivalent cations concentration in the water solution, either in the sample A or B, being most common calcium and magnesium (Ca+2, Mg+2). That can originate from nature   (dissolution   of    limestone)    or   by man actions (disposal of industrial effluents). In supersaturation conditions, these cations react with anions in the water, forming precipitates (Brazil, 2011; Sousa et al, 2016).
 
 
The values recorded in the study can be said to be classified as not hard (29.37 to 34.69 mg/L) in the East, moderately hard (89.28 to 118.60 mg/L) in the central, South and North regions, and hard (172.82 to 218.82 mg/L) in the Western region. Despite presenting statistical difference between the areas, the observed results are in accordance with the standards of the law.
 
The statistical difference observed (p <0.007) can be attributed to anthropic action on the receptors of residences with the accumulation of calcium and magnesium in the water pipes.  However, Lima (2015) stated that high levels of hardness do not cause health disorders to population.
 
The result from analysis presented values ​​between 48.9 and 62.9mg/L independently of samples origin A and B, below the limit established by law (250 mg/L)  presenting statistically significant differences between zones. Chloride (chlorine in the ion form of Cl-1) is one of the most common ions in natural waters and pollution indicator for domestic sewage. This justifies the water portability studied at the reception points and capture in this parameter, and the absence of salt taste with laxative properties (Filho et al., 2015). The amount of chlorides in the samples A and B presented no statistical significant difference (p = 0.136). This confirms the research by Vanuchi et al. (2014) and Moreira e Condé (2015) where they studied the presence of chlorides in the cities of Ubá / MG and Ariquemes/RO, which presented similar results to those of this research, with low levels of chloride between 18 and 20 and 19.3 and 35.4, respectively.
 
Nitrate ion (NO3-) is a byproduct of nitrogen cycle (Stüeken et al., 2016).It is the inorganic contaminant of concern in groundwater which may be from sewage and fertilizer application (Baird and Cann, 2011). The results found in the quantification of nitrate presented a statistical difference, being equal in East and South zones with the averages observed around 1.8mg/L.
 
The alkalinity results were between 87.1 and 96.2mg / L in zones studied showing that the analyzed water had no major changes by organic matter decomposition processes, effluent discharges or by metabolism of microorganisms through their respiratory activity and release of carbon dioxide.
 
Although the Brazilian legislation does not mention a maximum permissible value for the parameter, Libânio (2010) describes that the alkalinity of natural waters in the country is less than 100 mg/L of calcium carbonate (CaCO3). This study presented no statistical difference among the regions; however the samples A and B expressed statistically different results, probably due to the presence of CaCO3 originating from rock formations.
 
The physical parameters shown in Table 2 of the colour of the water supply of the analyzed areas were observed standard values, where the maximum value found was verified in the West region. The result was not statistically
different (p ≤ 0.05) between the zones and between samples A and B studied.
 
Turbidity is related to the presence of suspended solids  in the water, which act to reduce the transparency (Paludo, 2010). High turbidity values highlight the undesirable appearance of water and suspended solids can provide shelter for pathogenic microorganisms (Perpétuo, 2014).
 
The results for the analyzed samples presented a maximum value of 5uT. The East zone presented results statistically difference for the other zones. Statistical difference was found (p = 0.027) in the samples A and B. This can be attributed to the possible presence of solids waste in household receivers of South Zone, which presented the highest rates. The highest value was found in the average of the samples B South Zone, and the lowest averages in sample A of the East Zone. Values below the maximum permissible values were common in the analysis and the highest value observed can be explained by the lack of maintenance of the water with the presence of solid waste. Some researchers analyzed water intended for human consumption and the result observed for turbidity was similar to this research. Vitó et al. (2016) analyzed possible contamination in artesian well water in the state of Rio de Janeiro and obtained average results of 0,77uT as compared to the 5uT obtained in the research.
 
In relation to the microbiological analysis of total coliforms, thermotolerant coliforms and Escherichia coli, there were presence of total coliforms and thermotolerant coliforms in the study areas except Escherichia coli in the south. The highest average value of total coliforms was recorded in the East Zone (274.19 NMP) and Central Zone (224.89 NMP), followed by South Zone (75.19 NMP), West Zone (NMP 60.04) and North zone (35.55 NMP) (Table 3).
 
 
The water coliform contamination is important to specify the possibility of pathogenic microorganisms that can transmit waterborne diseases (Moura et al., 2009). The highest value of thermotolerant coliforms was positive in the West region (24.64 NMP), followed by East region (15.20 NMP). The lowest average value was found in the central region (6.96 NMP). The presence of thermotolerant coliforms indicates the possibility of fecal contamination and enteric pathogenic microorganisms (Silva et al., 2016).
 
The abundance of Escherichia coli was found in the East region (2.9 NMP), West region (2.75 NMP), North region (2.0 NMP) and the central region (1.8 NMP). The presence of E. coli is indicative of contamination that directly compromises the portability of water. The result of TC, TTC, and E. coli parameters does not differ statistically between the studied regions. Geldreich (1998) states that the runoff water is the main factor that causes changes in the microbiological quality of groundwater. This is because the water on contact with the ground carries organic matter, animal waste and particulate matter in large quantities to the well; this region still presents exposed cesspools in public via.
 
The lower results of total coliforms in the North and West region at these places have recently been changed by the water distributor, added to the constant maintenance on the network, reduce occurrences of contamination during distribution, disagreeing with the information presented in the report published by Water and Sewerage Company of Rio Grande do Norte-Brazil. It was observed that the water is distributed to households with compromised sanitary quality. This factor can be explained by the location of the well, probably by water contact with cesspools due to lack of sanitation in urban and rural areas, which is  one  of  the  main  causes  of  a large amount of contaminated water in Brazil (Scapin et al., 2012).
 
When comparing the means of all samples collected at the receptors (A) and collectors (B) of the households, higher values were observed for B receptors, obtaining 137.54 MPN and 2.37 MPN, for CT and E. coli, respectively. The value of the TTC from point B was similar to point A presenting 15.09 NMP. The results of the collection points A and B were statistically different just for CT. Thus, higher values ​​were found at the collectors of the households for this parameter, which indicates lack of maintenance. Regarding the TTC and E. coli parameters, the results of samples A and B are worrisome, since E. coli has as primary habitat the gastrointestinal tract of humans and other animals and is commonly responsible for urinary infections and diarrhea.


 CONCLUSION

It can be concluded that, in relation to the physical parameters, color and turbidity recorded higher results in the collectors of homes surveyed, identified the lack of maintenance of these. As chemical analyses of pH, chlorides and alkalinity not described large changes between the studied areas, since the hardness and nitrate analyses were higher in places where there is difficulty in sanitation or where there was a greater chance of contamination water, like sewage in the sky and garbage. For the studied microbial tests, it was verified presence of coliform group bacteria at all points in less than one of the collection, being the major contamination in the receivers. This is justified by the lack of maintenance and lack of prohibition of sealing of these collectors, allowing the access of rodents, insects and other carriers of microorganisms; and leaks in the piping that distributes water throughout the city may also be responsible for contamination.
 
Thus, the water consumed at collection points in the areas of the city of Mossoró presents physicochemical indices used and microbiological indices in disagreement with a legislation governing portability. So there is need to develop a supply company check critical points of the pipe mesh to minimize bacterial contamination pollution indicators.


 CONFLICT OF INTERESTS

The authors have not declared any conflict of interests.

 



 REFERENCES

Al-Mudhaf HF, Alsharifi F, Abu-shady A (2009). A survey of organic contaminants in household and bottled drinking waters in Kuwait. Science Total Environmental 407(5):1658-1668.
Crossref

 

Baird C, Cann M (2011). Química Ambiental. Porto Alegre: Bookman. Available at: 

View

 
 

Blank DE, Vieira JG (2014). Caracterização físico-química e microbiológica de água de poços rasos do bairro Três Vendas, Pelotas-RS. Vetor, Rio Grande 24(1):02-17.

 
 

Brazil (2011). Ministry of Health. Ordinance n.º 2.914, 12 December 2011. Dispõe sobre os procedimentos de controle e de vigilância da qualidade da água para consumo humano e seu padrão de potabilidade. Official Diary of the Union, Brazil.

 
 

Cabral JPS (2010). Water microbiology. Bacterial pathogens and water. International Journal of Environmental Research and Public Health 7(10):3657-3703.
Crossref

 
 

Choi H, Song M, Lee E, Ryu J (2013). The toxicogenomic study on Persistent Organic Pollutants (POPs) in human hepatoma cell line. Biochip Journal 7(1):17-28.
Crossref

 
 

Cody RP, Smith JK (2004). Applied statistics and the SAS programming language 5th ed New Jersey: Prentice Hall p 592.

 
 

Eaton AD, Clesceri LS, Greenberg AE (2012). Standard Methods for the Examination of Water and Wastewater. APHA AWWA WEF 22ª ed. 2012.

 
 

Fatemeh D, Reza ZM, Mohammad A, Salomeh K, Reza AG, Hossein S, Maryam S, Azam A, Mana S, Negin N, Reza KA, Saeeed F (2014). Rapid detection of coliforms in drinking water of Arak city using multiplex PCR method in comparison with the standard method of culture (Most Probably Number). Asian Pacific Journal of Tropical Biomedicine 4(5):404-409.
Crossref

 
 

Fernandes NC, Scalize OS (2015). Comparação entre dois métodos para determinação da qualidade da água tratada. Ciência and Engenharia 24(2):85-93.
Crossref

 
 

Filho JRF, Filho JSS, Cavalcanti PMM, Bezerra JDC, Freitas JCR, Freitas JJR, Freitas JR (2015). Avaliação da qualidade físico-química e microbiológica da água de barreiro utilizada no fabrico de queijo artesanal em Jucati - PE. Revista Brasileira de Tecnologia Agroindustrial 9(02):1920-1931.
Crossref

 
 

Funasa - National Health Foundation (2006). Manual de Saneamento: engenharia de saúde pública 3. ed. Brasília: Health Communication and Education Advisory.

 
 

Geldreich EE (1998). The Bacteriology of water in collier, L; Microbiology and Microbial infections 9th edition London pp 351-363.

 
 

Inyang M, Dickenson E (2015). The potential role of biochar in the removal of organic and microbial contaminants from potable and reuse water: A review. Chemosphere 134(1):232-240.
Crossref

 
 

Libânio M (2010). Fundamentos de qualidade e tratamento de água 3. ed. Campinas: Átomo.

 
 

Lima CT, Silva DE, Melo FHFA, Padua NTBM, Lima SF, Brião FS (2016). Avaliação dos indicadores da qualidade da água do sistema de distribuição do Serviço Autônomo de Água e Esgoto - SAAE de são Miguel Dos Campos/AL. Ciências exatas e tecnológicas, Maceió 3(3):73-82.

 
 

Lima RB (2015). Análise físico-química da água de três poços subterrâneos do município de Mossoró-RN. Revista Química: Ciência, Tecnologia e Sociedade 4(2):9-23.
Crossref

 
 

Morais WA, Saleh BB, Alves WS, Aquino DS (2016). Qualidade sanitária da água distribuída para abastecimento público em Rio Verde, Goiás, Brasil. Cadernos Saúde Coletiva 24(3):361-367.
Crossref

 
 

Moreira DA, Condé NM (2015). Qualidade das águas de minas no perímetro urbano do município de Ubá-MG. Multi-Science Journal 1(1):84-89.
Crossref

 
 

Moura RS, Pelli A, Terra APS, Okura MH (2009). Qualidade da água de minas em área urbana na cidade de Uberaba (MG). Revista Baiana de saúde pública 33(2):231-242.

 
 

Oliveira TMBF, Souza L, Castro SSL (2009). Dinâmica da série nitrogenada nas águas da bacia hidrográfica Apodi/Mossoró/RN-Brasil. Eclética Química 34(3).
Crossref

 
 

Paludo D (2010). Qualidade da Água nos poços artesianos do Município de Santa Clara do Sul. Bachelor's thesis.

 
 

Perpétuo EA (2014). Parâmetros de caracterização da qualidade das águas e efluentes industriais. São Paulo: CEPEMA-USP 1:90.

 
 

Scapin D, Rossi EM, Moro D (2012). Qualidade microbiológica da água utilizada para consumo humano na região do extremo oeste de Santa Catarina, Brasil. Revista do Instituto Adolfo Lutz 17(3) 593-596.

 
 

Silva LR, Cunha AHN, Costa e Silva SM, Souza JMF (2014). Avaliação de parâmetros físico-químicos da água de irrigação utilizada em um pivô central em Goiânia-GO. Global Science and Technology 7(3):96-102.
Crossref

 
 

Silva TC, Chaves QS, Romeiro SS, Fortuna JL (2016). Coliformes em fontes públicas de água no distrito de Santo Antônio, Teixeira de Freitas/BA. Ciência and Tecnologia 8 (special): 1-9. View

 
 

Sousa NCF, Gazola HQGB, Alves ERS, Silva OB (2016). Análise físico-química e bacteriológica de coliformes totais e termotolerantes da água de consumo distribuída aos alunos de 3 creches privadas do setor leste da cidade de Porto Velho - Rondônia. Saber Científico 5(1):24-32.

 
 

Sousa SS, Silva WS, Miranda JAL, Rocha JA (2016). Análise físico-química e microbiológica da água do rio Grajaú, na cidade de Grajaú - MA. Ciência e Natura 38(3):1615-1625.
Crossref

 
 

Spiegel MR, SCHILLER JJ, SRINIVASAN RA (2013). Probabilidade e Estatística -: Coleção Schaum. Bookman Editora.

 
 

Stüeken EE, Kipp MA, Koehler MC, Buick R (2016). The evolution of Earth's biogeochemical nitrogen cycle. Earth-Science Reviews 160(1):220-239.
Crossref

 
 

Tong Y, Yao R, HE W, Zhou F, Chen C, Liu X, Lu Y, Zhang W, Wang X, Lin Y, Zhou M (2016). Impacts of sanitation upgrading to the decrease of fecal coliforms entering into the environment in China. Environmental Research 149(1):57-65.
Crossref

 
 

Vanuchi VCF, Serpa ASH, Santos RR, Baptista JAA, Zan RA (2014). Analise físico-químicas de águas oriundas das principais lagoas e poços do garimpo Bom Futuro - Ariquemes/RO. South American Journal of Basic Education, Technical and Technological 1(1):19-28.

 
 

Vitó CVG, Silva LJBF, Oliveira KML, Gomes AT, Nunes CRO (2016). Avaliação da qualidade da água: determinação dos possíveis contaminantes da água de poços artesianos na região noroeste fluminense. Acta Biomedica Brasiliensia 7(2):59-75.
Crossref

 

 




          */?>